Projects |
Psychrometric Chart |
Processes |
| Name | Start point | End point | Q, kW | W, kg/h | |||||||
| No | t, °C | φ, % | L, m³/h | No | t, °C | φ, % | L, m³/h | ||||
| Name | Start point | End point | Q, kW | W, kg/h | ε | tc, °C | |||||||||||||||||||||||
| No | t, °C | twb, °C | tdp, °C | φ, % | d, g/kg | I, kJ/kg | ρ, kg/m³ | Pp, Pa | Ps, Pa | L, m³/h | G, kg/h | No | t, °C | twb, °C | tdp, °C | φ, % | d, g/kg | I, kJ/kg | ρ, kg/m³ | Pp, Pa | Ps, Pa | L, m³/h | G, kg/h | ||||||
Settings |
Orientation |
Air flow |
Examples |
Winter 1

1. Heating
Heating by an AHU air heater.
Download projectWinter 2

1. Heating
Heating by an AHU air heater.
2. Steam humidification
Humidification by an AHU steam humidifier.
Download projectWinter 3

1. Heating
Heating by an AHU air heater.
2. Mixing
Mixing of the AHU supply and return air flows.
3. Angle factor
Cooling by the room heat loss.
Stipulation of idem or close match of the following points on the chart shall be fulfilled:
- Start point of the second flow of the process #2.
- End point of the third process #3.
Winter 4

1. Heating
Heating by an AHU air heater.
2. Heating
Heating by a unit heater.
3. Mixing
Mixing of the air flows of AHU and unit heater.
4. Angle factor
Cooling by the room heat loss.
Stipulation of idem or close match of the following points on the chart shall be fulfilled:
- Start point of the process #2.
- End point of the third process #4.
Winter 5

1. User
Heating by an AHU wasteheat exchanger.
Angle factor process could be used instead of the user process.
2. Heating
Heating by an AHU air heater.
Download projectSummer 1

1. Cooling
Cooling by an AHU cooling coil.
2. Angle factor
Heating and humidification by heat and moisture gain of the room.
Download projectSummer 2

1. Mixing
Mixing of the AHU supply and return air flows.
2. Cooling
Cooling by an AHU cooling coil.
3. Angle factor
Heating and humidification by heat and moisture gain of the room.
Stipulation of idem or close match of the following points on the chart shall be fulfilled:
- Start point of the second flow of the process #1.
- End point of the third process #3.
Summer 3

1. Cooling
Cooling by an AHU cooling coil.
2. Cooling
Cooling by a split system.
3. Mixing
Mixing of the air flows of AHU and and split system.
4. Angle factor
Heating and humidification by heat and moisture gain of the room.
Stipulation of idem or close match of the following points on the chart shall be fulfilled:
- Start point of the process #2.
- End point of the third process #4.
Summer 4

1. Adiabatic dehumidification
Dehumidification by an AHU adsorption dehumidifier.
2. Cooling
Cooling by an AHU cooling coil.
3. Angle factor
Heating and humidification by heat and moisture gain of the room.
Download projectSummer 5

1. Adiabatic humidification
Direct evaporative cooling in an AHU trickling spray chamber.
2. Angle factor
Heating and humidification by heat and moisture gain of the room.
Download project